PRODUCT DESCRIPTION
Donor
Living or deceased Australian donor.
Source Tissue
Human heart.
Treatment
Antibiotic - streptomycin and penicillin.
Process Method
Valve is dissected from the donor heart and measured for size.
Cryopreserved at a controlled rate in 10% DMSO.
QC Testing
Microbiological culture - sampled throughout retrieval and processing including just prior to final packaging.
Tested for competency.
Packaging
Individually packaged in CryoLoc cryogenic packaging system.
Irradiation
Not applicable
STORAGE
Stored at or below -135°C in gas phase liquid nitrogen.
TRANSPORT
Transported in a dry shipper at or below -135°C .
ORDERING INSTRUCTIONS
Where possible place order 2 business days prior to the delivery date specifying the size of allograft required.
Product | Billing Code |
---|---|
Pulmonary Valve | TBV02 |